Symptoms
SBL-SVR-00051, SBL-ADM-01086Currently we are using the Call Center Object Manager and the EAI Object Manager. I have found a need to change a parameter in the named subsystem used by the EAI Object Manager, but I don't want that change to effect users on the Call Center Object Manager.Here is my approach:
1) Make a copy of the ServerDataSrc named subsystem - call is NYSServerDataSrc. I have no problems here.
2) Make changes to NYSServerDataSrc, leave original ServerDataSrc alone. No problems here.
3) I would like to associate NYSServerDataSrc with the EAI Object Manager, but I do not know where to make the change(s). Could you please help me out here?
Cause
Solution
For the benefit of others :-SUMMARY : Customer wanted to change the default Server Data Source (ServerDataSrc) of a component with a custom one.
The data source parameter (alias DataSource) is a fixed parameter in the component definition and cannot be changed at the component level.
SOLUTION : Either create a new component definition or reconfigure the component definition to change fixed parameters for the existing component.
To reconfigure compdef in the GUI by Use Navigation > Site Map > Administration - Server Configuration > component definition view.
NOTE**
a) Please refer to the following sections before you start reconfiguring to understand the impact on the system resources required when you reconfigure the server.
Siebel System Administration Guide > Configuring Siebel Servers > Advanced Configuration Tasks > Reconfiguring Siebel Server Component Definitions
b) Also, please make sure that you test this well before you try this on production.
c) Please take a backup of your siebns.dat file from your Gateway Server before you attempt this.
The same can be done using Server Manager. The following is an example session of this being done at the server manger.
...
srvrmgr> reconfig compdef ecustomerobjmgr_enu
Command completed successfully.
srvrmgr> change param datasource=serverdatasrc1 for compdef ecustomerObjMgr_enu
Command completed successfully.
srvrmgr> commit reconfig compdef ecustomerobjmgr_enu
Command completed successfully.
...
Note: To cancel changes made before commiting, use the following command.
cancel reconfig compdef ecustomerobjmgr_enu
KEYWORDS :
Change modify fixed parameter component definition Reconfigure Reconfiguring Server
ERRORS:
SBL-SVR-00051 : Cannot modify a fixed parameter
SBL-ADM-01086 : Cannot change fixed parameter %1
Applies to:
Siebel System Software - Version 7.5.2.214 [16066] and laterz*OBSOLETE: Microsoft Windows 2000
Version: 7.5.2.214 [16066]
Database: Oracle 9.2.0.2
Application Server OS: Microsoft Windows 2000 Server SP 3
Database Server OS: HP-UX 11.0
This document was previously published as Siebel SR 38-1020255121.
Symptoms
SBL-SVR-00051Once in a while, we encounter incidents wherein we are unable to log on properly to our eConsumersector application. It seems that it is unable to recognize the username and/or password. However, access via the dedicated web client works fine in such cases. To resolve the issue, we have to restart the Siebel Server and the Gateway Server. Access after this works fine afterwards.
We have not yet been able to determine what causes this nor notice any patterns of occurrences. But the problem seems to be an inability to do database authentication. A possible cause may be that we are taking offline backups, which brings down the database (and during time, the Siebel Server and Gateway Servers remains running as NT services). After the backup, the database is brought back up. When the issue happens, we are able to get to the logon screen but can no longer logon properly.
Any idea why this is happening? This issue is crucial because we are going to upgrade our production system in a week's time.
Cause
Configuration/ SetupSolution
For benefit of other readers, customer encountered following issues:1. Once in a while, we encounter incidents wherein we are unable to log on properly to our eConsumersector application. It seems that it is unable to recognize the username and/or password. However, access via the dedicated web client works fine in such cases. To resolve the issue, we have to restart the Siebel Server and the Gateway Server. Access after this works fine afterwards.
We have not yet been able to determine what causes this nor notice any patterns of occurrences. But the problem seems to be an inability to do database authentication. A possible cause may be that we are taking offline backups, which brings down the database (and during time, the Siebel Server and Gateway Servers remains running as NT services). After the backup, the database is brought back up. When the issue happens, we are able to get to the logon screen but can no longer logon properly.
GenericLog GenericError 1 2003-06-05 20:51:13 An Oracle database error has occurred. Possibly the database name is invalid.
Please continue or ask your systems administrator to check your application configuration if the problem persists.
GenericLog GenericError 1 2003-06-05 20:51:13 ORA-12154: TNS:could not resolve service name
Solution
The error ORA-12154 is a typical error message reported when service name specified during connection in this case via ODBC data source is not defined in tnsnames.ora file, or mis-spelt or the file is corrupted or the parameter "names.default_domain" in sqlnet.ora file does not match the suffix for the service name defined in the tnsnames.ora file.
For example,
tnsnames.ora
sales.siebel.com = xxxxxx
sqlnet.ora
names.default_domain = siebel.com
If you are able to connect via dedicated client but not via thin client and the logon screen is not displayed, you must review FAQ: FAQ 1773: What are the steps to troubleshoot the error message: “The server you are accessing is either busy or experiencing difficulties......” in a Siebel 7 Web client user browser? on SupportWeb. Also review Technical Note 388: How to configure Siebel Object Manager (SOM) in Siebel 7 available on SupportWeb. The logon screen could also possibly not displayed if the tasks within object manager cannot be spawned any further.
We recommend that during Oracle backups, please shutdown all the Siebel Services and Oracle Services prior to performing backup. Restart Oracle Services and then Siebel Services when you are ready to allow users to log in.
2. We have added new Enterprise Server to the environment both sharing common Gateway Server. We also created new named subsystem called ‘ServerDataSrcQA’. When we try to change the parameters ‘OM – Data Source’ and ‘OM – Named Data Source’ for the component eConsumerSector Object manager, we receive the following error:
SVR-00051 'Cannot modify fixed parameter'.
How can we successfully change the object manager parameters?
Solution
ServerDataSrc is default named subsystem provided within Siebel application. The new subsystem is only required if want to have a unique parameters for your environment otherwise standard named subsystem should be suffice.
Basically, one is able to change the parameter on customized component created. If you try to change the parameter for the standard components, you will receive the error SVR-00051 'Cannot modify fixed parameter'.
Change Request 12-179ZB3 has been raised to address this in future release.
Customer had specified the standard named subsystem ‘ServerDataSrc’ for the standard component parameters and therefore, they did not require any actions to be taken. No errors are encountered during the operation of the system.
If you would like to remove the new subsystem that you have created, you must do this using command line server manager (srvrmgr). The command is as follows:
srvrmgr> delete named subsystem <subsystem_alias_name>
No comments: